Launch Your Adventure
Description
ATF has determined that these initiators are not regulated explosive materials under 18 U.S.C., Chapter 40, and 27 CFR, Part 555. Following the Safety Explosives Act of 2003, which introduced regulatory requirements for ALL igniters.
MJG Firewire Initiators. These come with 3 foot leads, are pre stripped, and conveniently coiled for compact storage. Ideal for ejection charges and are sold individually.
Specifications are as follows:
| Bridgewire Resistance | Maximum No-Fire Current | Minimum All-Fire Current | Recommended Minimum Firing Current | Recommended Nominal Firing Current | Maximum Test Current |
|---|---|---|---|---|---|
| 1 ohm ± .2 ohms | .30 amp. (300milliamp.) | .60 amp (600 milliamp.) | .75 amp | 1.00 amp | .04 amp (40 milliamp.) |
Any pictures displayed are for reference only and may be different from the product shown for sale. Customers are responsible for verification.